External signal security level change function specification
- S2C1255
- 0: Invalid
- 1: Enabled
When enabled, the following input addresses become available:
The following special input signals are newly prepared.
#40773 |
#40772 |
#40771 |
#40770 |
Security selection |
Security selection |
Security selection |
Security selection |
Safety mode |
Management mode |
Edit mode |
Operation mode |
The follow decode decides how the operation changes according to the signal input:
#40773 |
#40772 |
#40771 |
#40770 |
Security mode |
OFF |
OFF |
OFF |
OFF |
A current mode is maintained. |
OFF |
OFF |
OFF |
ON |
Operation mode |
OFF |
OFF |
ON |
OFF |
Edit mode |
OFF |
ON |
OFF |
OFF |
Management mode |
ON |
OFF |
OFF |
OFF |
Safety mode |
OFF |
OFF |
ON |
ON |
Operation mode |
OFF |
ON |
OFF |
ON |
Operation mode |
ON |
OFF |
OFF |
ON |
Operation mode |
OFF |
ON |
ON |
OFF |
Edit mode |
ON |
OFF |
ON |
OFF |
Edit mode |
ON |
ON |
OFF |
OFF |
Management mode |
OFF |
ON |
ON |
ON |
Operation mode |
ON |
OFF |
ON |
ON |
Operation mode |
ON |
ON |
OFF |
ON |
Operation mode |
ON |
ON |
ON |
OFF |
Edit mode |
ON |
ON |
ON |
ON |
Operation mode |
NOTE: This feature only works when the controller is operating in 'Remote' mode. When note in remote mode, the security mode remains unchanged.
Limitations
When the password protection function is effective:
- The change at the security level with the external signal is assumed to be improper.
When the password protection function is invalid:
- The change at the security level is assumed to be improper on the security screen at a remote mode.