For more information, reference Manual 186803-1CD Yaskawa Cockpit Instructions
Computer Requirements
- Microsoft Windows 10 or Windows Server (Microsoft Windows 10 Pro (64bit) recommended)
- Memory: 16GB Minimum
- Hard Drive: 500GB Minimum (5TB Recommended)
- CPU: Core i7 4Core
- Web Browser: Google Chrome
Controller Requirements
- Verify controller software is at minimum version:
YRC1000micro YBS2.2100A-00 or later YRC1000 YAS2.80.00A-00 or later DX200 DN2.81.00A-00 or later DX100 DS4.41.00A-00 or later RM100 RMX1.20.00A-00 or later - All robot controllers are connected to the LAN with a unique IP address
Controller Setup
- In Maintenance Mode, turn on Yaskawa Cockpit option function
- Under I/O, turn on CMD REMOTE SEL for all controllers
- Configure backup to “RAMDISK” under SETUP > AUTO BACKUP SET
- For YRC1000micro/YRC1000 set job under Job Monitor
- For DX200/DX100 set D-Variable for Production Volume
- Set controllers to Remote Mode
Yaskawa Cockpit Hierarchy
- Yaskawa Cockpit uses the following hierarchy to organize controllers. It is recommended to determine your structure before starting because you can’t reorganize controllers after they’re created. NOTE: You can have as many lines and cells, but Yaskawa Cockpit is limited to a single factory. Controller count is determined by hard drive size, and data being gathered. Please consult with your Yaskawa representative to determine maximum.