Open Web App by opening a browser and navigating to localhost:8080/YCPApp
Go to SETTINGS > License Management and click Browse to add the license file for Robot Recorder.
Add Data Collector
In WebApp, go to SETTINGS > R/C Settings > Data Collection and click Add
Click “Import” and browse to Robot Recorder\DC\RobotRecorder.JSON
Click Register to add a data collector.
Go to SETTINGS > Initial Settings > Controller. Click the pencil button to edit the controller. Click the check box for Robot Recorder under the Data Collection Setting.
Add DW to Controller
Go to SETTINGS > Initial Settings > Add On and click Add. Add the following:
Add DLL to Analysis Library
Copy DLL from USB\RobotRecorder\RobotRecorderDLL to C:\Program Files\YASKAWA\YASKAWA Cockpit\DcApp\RobotDC\AnalysisLibrary