1.1 Arrangement of Units and Circuit Boards
2.1 Protection Through Security Mode Settings
2.1.1.1 Changing Security Mode
3.2 Inspection of the YRC1000micro
3.2.1 Inspection of the Case and the Body
3.3 Power-Supply Voltage Check
3.5 Inspection of Emergency Stop Button
3.6 Inspection of Enable Switch
3.8 Inspection of Air Filters (Environmental Resistance Model (ERBR-100-xxxxxxx-A01) Only)
4 Preparation before Replacing Parts
5.1 Replacement of Cooling Fan
5.3 Replacement of Air Filters (Environmental Resistance Model (ERBR-100-xxxxxxx-A01) Only)
6 Operations after Replacing Parts
6.1.1 Home Position Calibration
6.1.2.1 Registering All Axes at One Time
6.1.2.2 Registering Individual Axes
6.1.2.3 Changing the Absolute Data
6.1.2.4 Clearing Absolute Data
6.1.3 Home Position Posture of Manipulator
6.2 Position Deviation Check Using the Check Program
6.3 Checking of the Check Program
6.3.1 Motion of the Check Program
6.3.2 Checking of the Check Program
6.3.3 Home Position Data Correction
6.4 Setting the Second Home Position (Check Point)
6.4.1 Purpose of Position Check Operation
6.4.2 Procedure for the Second Home Position Setting (Check Point)
6.4.3 Procedure after the Alarm
7.3.1.1 GENERAL PURPOSE Input Window
7.3.1.2 General-Purpose Simple Window
7.3.2.1 General-Purpose Output Window
7.3.2.2 General-Purpose Output Simple Window
7.3.2.3 Modifying the Output Status
7.3.3.2 Specific Input Simple Window
7.3.4.1 Specific Output Window
7.3.4.2 Specific Output Simple Window
7.3.5.2 External Input Detail Window
7.3.6.1 External Output Window
7.3.6.2 External Output Detail Window
7.3.8.1 Direct Search on the General Purpose/Specified Input/Output Window
7.3.9.1 Direct Search on the General Purpose/Specified Input/Output Window
7.3.10 Modification of the Signal Name
7.3.10.1 Direct Modification on the General Purpose/Specified Input/Output Window
7.3.10.2 Modification from the Menu
7.4 System Monitoring Time Display
7.4.1 System Monitoring Time Display Window
7.4.2 Individual Window of the System Monitoring Time Display
7.4.3 Initializing the System Monitoring Time Display
7.5.2 Change the Listing Order of Alarm History
7.5.3 Alarm History Detailed Information Window
7.5.4 Clearing the Alarm History
7.6.1 I/O Message History Window
7.6.2 Clearing the I/O Message History
7.7 Position Data When Power Is Turned ON/OFF
7.7.1 Power ON/OFF Position Window
7.9.1.1 Changing the Monitor Items
7.9.1.2 Clearing Maximum Torque Data
7.10 State of the Robot Drop Tolerance Error
7.10.1 Check the Robot Drop Tolerance
7.10.2 Display of the Drop Value Number Window
7.10.3 Display of the Drop Value Check Window
7.10.4 Clear the Times of the Drop Value Number
8.2.1 Displaying and Releasing Alarm
8.3.2 Display of Alarm Detail Window
8.3.3 Transition of Alarm Detail Window
9.1.1 System and General Operation
9.1.4 External Memory Equipment
9.2.1.2 Application Transaction Error
9.2.2 When the Error Is Indicated
9.2.2.2 Application Transaction Error
10 Job Data Simplified Restoration Function
10.2.1 How to Check Job Data Inconsistent Status
10.2.2 Job Data Restoration Method
10.2.2.1 Same Position Data Is Chained
10.2.2.2 Not-Registered Position Data Is Chained
10.2.2.3 Not-Chained Position Data Exists
10.3 If Fail in Simplified Restoration
10.3.2 If Data Inconsistency Alarm Occurs Again
11 LED Indicator on Circuit Board
11.1 LED Indicator on ACP 31 Board
11.2.0.1 The 7 SEG-LED Indicator Status (1-Digit Indication) of Each Unit at Error Occurrence
11.2.0.2 The 7 SEG-LED Indicator Status (4-Digit Indication) of Each Unit at Error Occurrence
12.1 About Program Upload Function
12.1.1 When the System Program Is Required
12.3 Restoration Procedure 1 (Writing the Program)
12.3.1 Determining Failure of SD Card
12.3.2 Preparation of SD Card for ACP31
12.3.3 Preparation of SD Card for Wiring the Program
12.3.4 Writing the System Program
12.4 Restoration Procedure 2 (Loading the Batch Data)
12.4.1 When the Batch Data Is “CMOS.BIN”
12.4.2 When the Batch Data Is “CMOSBK.BIN”
Comments
0 comments
Article is closed for comments.