1.2 Command Remote Setting for YRC1000micro
1.2.1 Remote Mode and Local Mode
1.2.2 Switching the Function by Command Remote Setting
1.2.3 Command Remote Setting Method
1.2.4 Command Remote State Displayed Window
1.3 Ethernet Cable Connections
1.4 Notes When Loading the Data
2 LAN Interface Setting and Network Communication Confirmation
2.1.2 LAN Interface Setting Item
2.2 Daylight Saving Time Setting
2.3 LAN Interface Setting Confirmation
2.3.1 LAN Interface Setting Confirmation Method
2.3.2 Information Displayed on the Network Service Window
2.4 Network Communication Confirmation
2.4.1 Network Communication Confirmation from Windows PC
2.4.2 Network Communication Confirmation from the YRC1000micro
3 High-Speed Ethernet Server Function
3.2.2 Batch Data Back-up Function Setting
3.3.2.1 Robot Control/Status Reading
3.3.2.2 Robot Control/Data Writing to Register
3.3.2.3 File Control (File Saving)
3.3.2.4 File Control (File Loading)
3.3.2.5 File Control (File List)
3.3.2.6 File Control (Deleting of file)
3.3.3.1 Alarm Data Reading Command
3.3.3.2 Alarm History Reading Command
3.3.3.3 Status Information Reading Command
3.3.3.4 Executing Job Information Reading Command
3.3.3.5 Axis Configuration Information Reading Command
3.3.3.6 Robot Position Data Reading Command
3.3.3.7 Position Error Reading Command
3.3.3.8 Torque Data Reading Data
3.3.3.9 I/O Data Reading / Writing Command
3.3.3.10 Register Data Reading / Writing Command
3.3.3.11 Byte Variable (B) Reading / Writing Command
3.3.3.12 Integer Type Variable (I) Reading / Writing Command
3.3.3.13 Double Precision Integer Type Variable (D) Reading / Writing Command
3.3.3.14 Real Type Variable (R) Reading / Writing Command
3.3.3.15 16 Byte Character Type Variable (S) Reading Writing Command
3.3.3.16 Robot Position Type Variable (P) Reading / Writing Command
3.3.3.17 Base Position Type Variable (BP) Reading / Writing Command
3.3.3.18 External Axis Type Variable (EX) Reading / Writing Command
3.3.3.19 Alarm Reset / Error Cancel Command
3.3.3.20 Hold / Servo On/off Command
3.3.3.21 Step / Cycle / Auto Switching Command
3.3.3.22 Character String Display Command To The Programming Pendant
3.3.3.23 Start-up (Job Start) Command
3.3.3.25 Management Time Acquiring Command
3.3.3.26 System Information Acquiring Command
3.3.3.27 Plural I/O Data Reading / Writing Command
3.3.3.28 Plural Register Data Reading / Writing Command
3.3.3.29 Plural Byte Type Variable (B) Reading / Writing Command
3.3.3.30 Plural Integer Type Variable (I) Reading / Writing Command
3.3.3.31 Plural Double Precision Integer Type Variable (D) Reading / Writing Command
3.3.3.32 Plural Real Type Variable (R) Reading / Writing Command
3.3.3.33 Plural 16 Byte Character Type Variable (S) Reading / Writing Command
3.3.3.34 Plural Robot Position Type Variable (P) Reading / Writing Command
3.3.3.35 Plural Base Position Type Variable (BP) Reading / Writing Command
3.3.3.36 Plural Station Type Variable (EX) Reading / Writing Command
3.3.3.37 Alarm Data Reading Command (for Applying the Sub Code Character String)
3.3.3.38 Alarm History Reading Command (for Applying the Sub Code Character String)
3.3.3.39 Move instruction command (Type Cartesian Coordinate)
3.3.3.40 Move Instruction Command (Type Pulse)
3.3.3.41 32 Byte Character Type Variable (S) Reading Writing Command
3.3.3.42 Plural 32 Byte Character Type Variable (S) Reading / Writing Command
3.3.3.43 Encoder Temperature Reading Command
3.3.3.44 Converter Temperature Reading Command
3.3.4.4 File List Acquiring Command
3.3.4.5 File Saving Command (Batch Data Backup)
3.3.5 Examples of Communication Packets
3.3.5.1 Status Information Reading
3.3.5.4 Plural I/O Data Reading
3.3.5.5 Plural I/O Data Writing
3.5.1 Network Communication Confirmation
3.5.2 Communication Setting Confirmation for Firewall and Security Software
3.5.3 Error Log Confirmation of High-speed Ethernet Server Communication
4.1.4 CMOS Saving Function via FTP
4.2.1 Enabling Setting for the FTP Function
4.2.2 Enabling the CMOS Saving Function via FTP
4.4.2 Example of Communication Procedure in Expand Mode (When Using FileZilla)
4.4.3 Saving CMOS Data by Using CMOS Saving Function via FTP
4.5.1 Network Communication Confirmation
4.5.2 Confirming the Communication Setting for Firewall and Security Software
4.5.3 Confirming the Function Mode
4.5.4 Confirming the Secure FTP Type and Version
4.6 FTP Job Overwrite Function
4.6.2 Parameter for Setting Function
5.2.1 Communication Target Setting
5.2.2 Command Remote OFF Setting
5.3 Preparation at the YRC1000micro Side
5.3.1 Command for Job Transmission
5.3.2 Command for Variable Transmission
5.3.4 Concurrent Task from Multiple Job
5.3.5.1 Parallel Execution Using NWAIT
5.3.5.2 Parallel Execution Using PSTART (Optional)
5.3.6 Axis Data Transmission Format
5.4 Preparation at the PC Side
5.5 Executing the DCI Function
5.7.1 Network Communication Confirmation
5.7.2 Communication Setting Confirmation for Firewall and Security Software
5.7.3 Confirming the Operation of the PC-side Application
5.7.4 Confirming That the Remote Setting is OFF
6.2 Preparation at the PC Side
6.3 YRC1000micro-side Setting and Operation
6.3.1 Enabling Setting for the FTP Function
6.3.2 Setting for the FTP Connection Condition
6.3.3 Selecting the FTP Function
6.3.4.2 Saving Files Except for Job
6.3.5.2 Loading File Except for Job
6.3.6.2 Verifying File Except for Job
6.3.7 Selecting Job and Data File
6.4.1 Network Communication Confirmation
6.4.2 Communication Setting Confirmation for Firewall and Security Software
6.4.3 Confirming the FTP Server Operation
6.4.4 Confirming That the Remote Setting is OFF
7 Internal Data Browsing Function by Using a Web Browser
7.3 Transmission Procedure Example
7.4.1 Network Communication Confirmation
7.4.2 Communication Setting Confirmation for Firewall and Security Software
8.1.3 General Information for When Using the Ethernet Server Function
8.3.1.3 Response to START Request
8.3.2.2 System Control Function
8.3.2.3 I/O Read/Write Function
8.3.3.1 Read-Out of Status for Mode, Cycle, etc
8.3.3.2 Read-Out of I/O Signals for the YRC1000micro
8.3.3.3 Write-In of I/O Signals for the YRC1000micro
8.3.3.4 Continuous Execution of Multiple Command
8.4.1 Network Communication Confirmation
8.4.2 Communication Setting Confirmation for Firewall and Security Software
8.4.3 Confirming the connection of the Ethernet Server Function
9.1.3 General Information When Using the Host Control Function
9.3.1 File Data Transmission Function
9.3.2 Manipulator Control Function
9.4.1 Network Communication Confirmation
9.4.2 Communication Setting Confirmation of Firewall and Security Software
10.2.1 Communication Target Setting
10.2.2 Command Remote to OFF Setting
10.3 Preparation at the PC Side
10.4 Executing the Standalone Function
10.4.1 Selecting the Standalone Function
10.4.2.2 Save a File Other Than Job
10.4.3.2 Load a File Other Than Job
10.4.4.2 Verifying the File Other Than the Job
10.4.5 Selection Mode of the Job
10.4.5.1 Single Selection Mode
10.4.5.2 Related Selection Mode
10.4.5.3 Switching the Selection Mode
10.4.6 Selecting a Job or Data File
10.5.1 Network Communication Confirmation
10.5.2 Communication Setting Confirmation for Firewall and Security Software
10.5.3 Confirming the Operation of the PC-side Application
10.5.4 Confirming That the Remote Setting is OFF
11.1 General Information About the Host Control System Function
11.1.1 List of Interlock for Command of Host Control Function
11.1.2 Command that Handle Axis Data
11.1.3 Response to MOV-type Command
11.1.4 Command for Multi-control Group and Independent Control Function
11.1.4.1 Command for Multi-control Group
11.1.4.2 Command for Independent Control Function
Comments
0 comments
Article is closed for comments.